QualEngine Training / Dimensional Results
P2 · Training · PPAP element 09 / Design record check

Dimensional resultsFull Dimensional Results

Definition

Dimensional inspection is the measurement, against the design record (drawing), of every dimension and characteristic one by one, with every measured value falling inside the tolerance band, submitted as the PPAP "Dimensional Results". The drawing must first beballooningballooned (every dimension given a balloon number), and the number of ledger rows then equals the number of dimensions — the two numbering systems must match so that a measured value can be traced to a specific dimension.

AIAG PPAP (4th edition), element 09 IATF 16949 · 8.6.1 Verification IATF 16949 · 8.3.5.1 Design output

1. Definition and purpose

Why "all dimensions" and not "sampling"

PPAP element 09 requires complete measurement of every dimension and characteristic on the design record, rather than sampling a few key dimensions. The reason: a missed dimension may be exactly the fit / assembly point the customer cares about, and an unnoticed deviation surfaces at vehicle assembly. Balloon the drawing first, one number per dimension; then ledger rows = number of dimensions with numbers matched one to one, so nothing is duplicated, nothing missed, and everything is traceable.

IATF 16949:2016 clause8.6.1requires that "the product is verified to conform to requirements, as planned and at the appropriate stages";8.3.5.1requires that design and development outputs "include or reference … acceptance criteria". Dimensional inspection is the physical evidence for these clauses: every dimension has a nominal value, a tolerance, a measured value, a judgment and a gage record.

Four questions the inspection record must answer

QuestionAnswer given by the record
What was measuredDimension number (balloon) corresponds to the drawing, with a clear feature description
What it should beDrawing dimension (nominal value) + tolerance band (direction, size)
What it actually isMeasured value + gage + measurement datum, with deviation calculated automatically
Can it be submittedEach dimension judged OK / NG; NG items are dispositioned and closed after re-measurement

2. Tolerance types and judgment

Five tolerance types and their judgment rules

First determine the tolerance type, then judge OK / NG: for a symmetric tolerance just look at |deviation|; for one-sided / asymmetric tolerances, judge against the upper and lower limits in the right direction. Get the type wrong and every judgment is wrong.

TypeExpressionJudgment rule
Symmetric tolerance ±12.00 ±0.05 (upper 12.05 / lower 11.95)Deviation = measured − nominal; |deviation| ≤ tolerance → OK
One-sided positive tolerance ++0.10 / 0 (nominal ≤ measured ≤ nominal + tolerance)Enter "nominal 0, tolerance = positive tolerance value" and judge deviation ≤ tolerance; or compare against the upper limit
One-sided negative tolerance −0 / −0.10 (nominal − tolerance ≤ measured ≤ nominal)Enter "nominal 0, tolerance = absolute value of the negative tolerance" and judge deviation ≥ −tolerance and ≤ 0
Asymmetric tolerance +/−+0.10 / −0.04 (upper and lower limits differ)Compare the upper and lower limits separately: upper = nominal +0.10, lower = nominal −0.04
Geometric tolerance (position / flatness)Flatness 0.05, position Φ0.10The measured value is an absolute value compared directly against the tolerance band; in this ledger it is entered as "nominal 0, deviation = measured"
Nominal 12.00 ±0.05 Measured 12.02 Deviation +0.02 OK (|deviation| ≤ tolerance) NG (out of tolerance) Deviation = measured − nominal = 12.02 − 12.00 = +0.02 Measured 12.06 → +0.06 > 0.05 → NG
Figure 2-1 Deviation and OK / NG judgment under a symmetric tolerance
Handling asymmetric / geometric tolerances

The symmetric "±" model can only be applied directly where the two directions are equal. For an asymmetric tolerance such as +0.10 / −0.04, entering it as "symmetric ±" in the workbench judges it wrongly — the direction information must be carried in as described in panel 01 (for example by expressing it as nominal 0 plus the tolerance in that direction, or by recording the upper and lower limits). For geometric tolerances (flatness / roundness / position) the measured value is an absolute value and is compared directly against the tolerance band.

3. Ballooning and numbering rules

Balloon first, then register

On the drawing, use a balloon(balloon) to mark every dimension / characteristic with a unique number (D1, D2, …), and the ledger is filled in the same number order.Ledger rows = number of dimensions, with numbers matched one to one. Measuring without ballooning easily leads to missed dimensions, duplicated measurements or mismatched results.

Ø12.00 ±0.05 D1 120.0 ±0.10 D2 Drawing (ballooned) One-to-one correspondence Dim. No. Feature Drawing Tol.± Measured Deviation Judgment D1 Hole dia. 12.00 0.05 12.02 +0.02 OK D2 Overall length 120.0 0.10 119.93 −0.07 OK D3 Step height 8.00 0.03 8.04 +0.04 NG Ledger (rows = number of dimensions)
Figure 3-1 Drawing balloon numbers mapped one to one to the inspection ledger

Numbering and registration discipline

Full coverageEvery dimension / characteristic on the drawing has a balloon number, with none missed.
UniquenessNumbers are not repeated within one drawing, so traceability and customer checking stay easy.
CorrespondenceLedger rows follow the number order, so each measured value can be matched to its position on the drawing.
Closed loopNG items must be dispositioned (rework / concession / design change) and re-measured, with the re-measurement result recorded separately.

4. Sign-off and revision control

The inspection record is also a controlled document

The dimensional inspection record is acontrolled document(IATF 16949 7.5.3 control of documented information): the current revision is controlled, obsolete revisions are withdrawn, and revisions are recorded. None of the three may be missing:

Three-level sign-offPrepared (metrology / quality engineer) → reviewed (technical supervisor) → approved (quality / customer interface owner), with signature + title + date.
Revision identificationThe revision number rises with each revision (A / 0 → A / 1 or B / 0), and users only ever see the current revision.
Revision recordRevision content, date, reviser and approver are traceable for every revision.

Sign-off page style (the same one built into the workbench)

ResponsibilityName (signature)TitleDateComment
Prepared by
Reviewed by
Approved by

The sign-off order cannot skip a level: preparation must be complete before review, and review must pass before approval. After a revision, the original approver (or a delegate) approves again. Once the three-level sign-off is complete, the result is submitted as PPAP element 09 together with the other documents.

5. Common mistakes

Five frequent mistakes

① Measuring only key / important characteristics and missing general dimensions, leaving gaps in the PPAP submission; ② balloon numbers do not match ledger row numbers, so measured values cannot be traced to specific dimensions; ③ one-sided / asymmetric tolerances entered as symmetric ±, judging the direction wrongly; ④ measured values carry no datum (the measured face is not stated), so re-measurement cannot be reproduced; ⑤ releasing on a single OK measurement while ignoring the process capability of that dimension (SPC / an initial process study should be run separately).

Pre-submission checklist

The drawing is ballooned, and dimension numbers match ledger rows one to one with none missed.
Every dimension has been measured, with units and measurement datum (face / axis) recorded.
The tolerance direction (one-sided / two-sided / asymmetric / geometric) is entered into the judgment logic correctly.
All dimensions judged OK; any NG item has been dispositioned and re-measured, with the re-measurement record traceable.
The result is signed off at three levels and submitted as PPAP element 09 together with the other documents.

6. Self-test

Self-test (5 questions)

Q1What is the difference between a full dimensional inspection and "sampling key dimensions"?
Sampling is easier and the customer does not require full inspectionOnly important characteristics need measuringMeasure, against the design record, every dimension and characteristic, with rows = number of dimensions
PPAP element 09 requires "all dimensions" — complete measurement of every dimension and characteristic on the design record, not sampling.
Q2Drawing 12.00 ±0.05, measured 12.06 — what is the judgment?
OK (it is close to 12.00)NG (deviation +0.06 > 0.05)Customer confirmation is needed
Deviation = 12.06 − 12.00 = +0.06 > tolerance 0.05 — beyond the upper limit, so it is judged NG.
Q3What is the purpose of ballooning?
To give every dimension a unique number, so that ledger rows = number of dimensions and match one to oneTo make the drawing look nicerTo mark the sequence of operations
Ballooning numbers every dimension and the ledger is filled in by number, ensuring nothing is duplicated or missed and each measured value can be traced to a specific dimension.
Q4With an asymmetric tolerance of +0.10 / −0.04, the correct action is to
Enter it directly as symmetric ±0.05Ignore it and judge against the nominal valueCompare the upper and lower limits separately (upper = nominal +0.10, lower = nominal −0.04)
An asymmetric tolerance has unequal upper and lower limits, so the directions must be compared separately; the symmetric ± model cannot be applied directly, otherwise the direction is judged wrongly.
Q5A dimension measures OK but its process capability is low — may it be released for submission?
Yes, a single OK measurement is enoughSPC / an initial process study should be run first to assess process stability before deciding on submissionNo need to consider it
A single OK measurement only shows that this piece conforms; process capability (Cpk) is a separate matter, so SPC / an initial process study should be run to avoid batch drift.

Hands-on practice: Dimensional Results workbench

OpenDimensional Results workbench, balloon a real or practice drawing first, then register all dimensions by number, complete the three-level sign-off and export it for archiving; then return toPPAP 18-element ledgerto track the remaining elements.

Based on the AIAG PPAP Manual (4th edition) / IATF 16949:2016 / AIAG APQP Manual (3rd edition, 2024)